Basic Info
  • Model NO.: S8 Exp
  • Type: Ultrasound Scanner
  • Group: Everyone
  • High Tech. of: 4D Imaging
  • Trademark: SONOSCAPE
  • HS Code: 90121810
  • Classification: Imaging Diagnostic Equipment
  • Certification: CE, SGS, FDA, ISO13485
  • Display: 15-Inch High-Resolution Color LCD Monitor
  • Different Languages: English, French,Spanish,Italian,Russian,German
  • Origin: China
Product Description
S8 Exp Portable Digital Color Doppler Ultrasound System
European Hot Sale S8 Exp Portable Color Doppler 4D Ultrasound Scanner  European Hot Sale S8 Exp Portable Color Doppler 4D Ultrasound Scanner
 
THE PIONEER OF DOPPLER ULTRASOUND IN CHINA
  
Overview
S8 Exp Color Doppler Ultrasound System adopts the advanced ultrasonic Doppler technologies, including the Full Digital Super-wide Band Beam Former, Digital Dynamic Focusing, Variable Aperture and Dynamic Tracing, Wide Band Dynamic Range,
Multi-Beam Parallel Processing, and etc. The ultrasound diagnostic software in ergonomic design can be customized and easily performed by users. The operation interface has multi-language settings and figure illustration. Complying with applicable international standards and regulations, the system is safe to use.
Based on the industry control computer technology and Linux operation system, the system is more flexible and stable. Moreover, the system supports maintenance and function upgrade through software upgrade, which raises product value and keeps the technological advancement. 
 
Advanced Technologies
New generation digital front-end technology
Multi-beam processing technology
Spatial compound imaging
μScan image processing technology
Tissue Harmonic Imaging
Invert harmonic imaging
High Pulse Repetition Frequency
Panoramic imaging
4D imaging
Graphic diagnosis icon
Elastography imaging
±     English
±     Simplified Chinese
±     Spanish
±     Russian
±     French
±     Italian
±     German
±     Norwegian

B mode: Five variable frequencies
LGC (two levels)
Tissue acoustic characteristics index
THI mode
PIH mode
Multi-beam
Image rotation
Compound imaging
Trapezoidal imaging
Color mode
PDI mode
DPDI mode
PW mode
HPRF support
Simult mode
FreeHand 3D
Biopsy function
Steer M mode
Biopsy enhance
Basic measurement package
Obstetrics measurement package
Gynecology measurement package
Cardiology measurement package
Abdomen measurement package
Vascular measurement package
Urology measurement package
Small parts measurement package
Pediatrics measurement package
TEI index
PW auto trace 

Standard Configurations
ECG function module
μScan function 
IMT measurement
DICOM transmission
DICOM Worklist
DICOM MPPS 3 / 32  
DICOM C-store
DICOM Q/R 
 
Optional Functions
DVD drive
4D imaging
Biplane dual live
Color M function
TDI mode
CW mode
Stress Echo function
2D Panoramic imaging
Color flow panoramic imaging
Elastography imaging 
 
Optional Accessories
Biopsy bracket
Color ink-jet printer
B/W video printer
Color video printer
Probe cable hanger
Foot switch
External DVD burner
Trolley
Transducer extender
 
 
Scan Methods
Electronic curved sector scan
Electronic linear array scan
Electronic phased array sector scan
Mechanical sector scan (convex probe)
Applications
Abdomen
Vascular
Cardiology
Gynecological/Obstetrics
Urology
Musculoskeletal
Interventional ultrasound
Small parts
Anesthesiology
Pediatrics
Orthopedic
Cephalic 
 
Imaging Modes
B mode
M mode
THI mode
CFM mode
PDI mode
TDI mode
PW mode
CW mode
HPRF
3D/4D mode
Color M mode
Steer M mode
Elastography imaging
 
 
Display Formats
Dual B
Quad B
B + Color
B + Color dual live
B + PDI
B + TDI
B + M
B + Color + M
B + PDI + M
B + TDI + M
±     Body Mark
±     Arrow
±     Distance
Trackball Sensitivity
±     1, 2, 3, 4, 5 ,6
Date/Time Setting
Date Format 
B + PW
B + Color + PW
B + PDI + PW
B + TDI + PW
B + CW
B + Color + CW
B + PDI + CW
Panoramic imaging
Trapezoidal imaging
 
 

 
  
Key Configuration
The saved image can be printed, saved to USB drive, DICOM storage server and DICOM printer server.
The saved cine can be saved to USB drive and DICOM storage server.
U1, U2 shortcut keys: can be set to save image, cine or volume data or set to print saved image, send saved image or data to USB drive, DICOM storage server or DICOM printer server.

Peripheral
Local Network
DHCP or Static IP
Enable DHCP, DICOM AE title and Mac address should be provided.
Enable Static IP, IP address, netmask, default gateway, DICOM AE title and Mac address should be provided.
Advance

±     Speed (10M, 100M, 1000M UNKNOW!)
±     Duplex (Semi Duplex, Full Duplex, Unknow!)
Ping IP Address function
 
Printer
Printer Driver
Video Invert
Default Printer
Net Printer IP

Measure
General
BSA

±     Eastern
±     Western
Cross Cursor Size
±     Small, Medium, Large
Measure Line Size
±     Small, Medium, Large
Dist Dash Line Disp.
±     On, Off
Vel. Cross Line Disp
±     On, Off
Ellip. Cross Line Disp
±     On, Off
Line ID Disp.
±     On, Off
Keep Result Window
±     On, Off
Freeze on Measures
±     Yes, No
Shortcut keys
±     Support performing obstetrics and gynecology measurements with shortcut keys. 10 shortcut keys can be set for each application.
Formula
Fetal weight estimation
Fetal growth curves


 
6 / 32
 
 
 
Age by EFW
CUA
BPD
HC
FL
Cereb
GS
RAD
TIB
BOD
OFD
AC
HL
CRL
Clav.
Ulna
FIB
Report
Logo
Operation Logo (connect the USB drive written with report logo (170*60 pixels, bmp format) to the ultrasound system and click the left or right arrow key to select the desired logo)

Title/Font
Title 1/2/3 (Font size can be set to 14, 16, 18, 20, 22, 24 or 26.)
Context (Font size can be set to12,13, 14,15,16.)
Title (Font size can be set to 14, 16, 18, 20, 22, 24 and 26.)
Subtitle (Font size can be set to 14, 16, 18, 20, 22, 24 or 26.)
Background Color

 
Text Color
Display Items For Report
Patient Information
Exam Information
Measurements (optional)
Image (optional)
Graphs (optional)
Comments (optional)
Preview button

DICOM
Image Storage
Add or delete server list
Remote Host Name, IP Address, DICOM AE Title, Port Number of DICOM storage server; Connect Timeout, Dimse Timeout, Repeat Count, Acse Timeout, Relate to CommitStore, Send After Every Image Stored and Send At End of Exam.

Commitment Storage
Add or delete server list
Remote Host Name, IP Address, DICOM AE Title, Port Number of DICOM Commitment storage; Connect Timeout, Dimse Timeout, Repeat Count, Acse Timeout, Synchronously Receive

N-EVENT-REPORT Message
Worklist
Add or delete server list
Remote Host Name, IP Address, DICOM AE Title, Port Number of DICOM worklist server; Connect Timeout, Dimse Timeout, Repeat Count, Acse Timeout, Max. Result.

MPPS
Add or delete server list
Remote Host Name, IP Address, DICOM


 
 
 
AE Title, Port Number of DICOM MPPS server; Connect Timeout, Dimse Timeout, Repeat Count, Acse Timeout
Print
Add or delete server list
Remote Host Name, IP Address, DICOM AE Title, Port Number of DICOM print server; Connect Timeout, print parameter pre-settings
Format, Priority, Medium, Orientation, Film Size, Film Destination, Magnification, Copies, Smoothing Type, Trim, Border, Empty Image, Color, Min Density, Max Density, Configure Information, Film Session Label

QR List
Add or delete server list
Remote Host Name, IP Address, DICOM AE Title, Port Number of DICOM QR List server; Connect Timeout, Dimse Timeout, Repeat Count, Acse Timeout, Max. Result.

Load Default
Load
New
Export/Import
System Information
 
 
System Parameters
Frame rate: up to 820f/ps (Probe dependent)
Grayscale Level: 256
Transducer Elements: Max. 256
 
 
B Mode
Gain: 1-255 adjustable
 
Scan Depth: 42.9cm (Probe dependent)
Image Zoom, Showing magnification (0.8-10 times)
TGC: 8 levels slider controls
Image Inversion: Left and Right, Up and Down
Panoramic imaging: achievable
Compound imaging: off, 1, 2
Focus: Up to 12, Focus span adjustable (Probe dependent)
Frequency: 5 bands adjustable
Chroma: 13 types selectable
Adaptive image fusion: 15 types selectable
l      μScan: 0, 2, 3, 7, 11
Line Density: 3 levels adjustable (High/Medium/Low)
Persistence: 0-95 selectable
Biopsy Guide Function: On/Off
Biopsy lines angle adjustable
Biopsy lines offset adjustable
Dynamic Range: 20-280 (Probe dependent)
Grayscale Curve: 7 selectable
Imaging width and position: adjustable
Power: 1-100 adjustable, one step each
Tissue acoustic characteristics:1400-1700
LGC: gain compensation for left or right part of image
Trapezoid Imaging: On/Off (Linear probe)
B steer mode (linear probe)
M-tuning function
 
 
Color Doppler/TDI Mode
l      Gain: 0-255
Frame Rate: up to 50 frames/sec (Probe dependent)

 
 
 
  
 
8 / 32
 
 
 
Size and position of color ROI: adjustable
Auto Focus (focus number:1)
Inversion: Up/Down, Left/Right
Flow Invert: On/Off
Frequency Range: 5 steps, adjustable
Wall Filter: 25-750Hz, adjustable
PRF: 0.5-12kHz (Probe dependent)
Line Density: 4 levels (low/medium/high/highest)
Color/Direction energy: 10 levels for color Doppler mode; 4 levels for TDI mode
Color baseline adjustment: ±15 steps
Persistence: 0-80 (Probe dependent)
 
B Reject: 0-255
Linear steer angle: 0, ±16, ±20 adjustable
M-tuning function
 
 
M Mode
Steer M mode: 3 sample lines, Display frame rate
Video Inversion (On/Off)
Chroma: 5 types
l      Display Format: H1/2, H1/4, V1/3, V1/2, V2/3, O1/4
Scan Speed: 6 levels adjustable
M Process: Switch between average and peak values
Power: 30-100 adjustable
 
 
Spectral Doppler Mode
Doppler Methods
PW (pulsed wave) Doppler
CW (continuous wave) Doppler
Triplex: On/Off
 
Sample Volume and Position for PW Doppler: 0.7-21mm adjustable
Video Inversion: On/Off
Spectrum Inversion: Achievable
Angle Correction: 0°, 60°, -60°
θ Angle Correction: correction range: 0 -72°
Spectral Real-time Trace: Achievable
Baseline Shift:17 steps selectable
Frequency Range: 5 steps
Wall Filter: 25-750 adjustable
PRF: 1-16kHz (PW) (Probe dependent)
PRF: 1-48KHz (CW) (Probe dependent)
Max Velocity Range
0.0004-16 m/s (PW) (Probe dependent)
0.0013-63 m/s (CW) (Probe dependent)

Scan Speed: 4 levels adjustable
Doppler Chroma: 5 kinds selectable
One-key Auto Optimization
Auto Adjusting Baseline
Auto Adjusting PRF
Auto Correcting Angle

Dynamic Range: 10 types selectable
l      Display Format:H1/2, H1/4, V1/3, V1/2, V2/3, O1/4
Steer Angle: 0, ±16, ±20,5 levels adjustable
 
 
3D Mode
Scan Mode: Lin and Sec, selectable
Z Scale: 0.3-2.0 adjustable (range reduced for few slices)
Z Angle: 10°-170° adjustable
Methods for cropping reviews
By trace (crop inner or outer image) By box (crop inner or outer image)
9 / 32
 
 
 
By eraser (big or small eraser)
Undo cut: undo last cut
Display Mode
Dual-split display
Quad-split display
3D Full Display
Contrast: 0-100 adjustable
Transparency: 0-100 adjustable
Brightness: 0-100 adjustable
Smoothness: 0-30 adjustable
3D Chroma: 0-12 adjustable
B Chroma: 1-13 adjustable
l      View angle: 0°, 90°, 180°, 270°
Restore: Volume/All/Curve, selectable
Render Mode: Vol, MaxIP, X ray
Orientation: Top, Bottom, Left, Right, Front or Back, selectable
l      Auto rotate: 45°, 90°, 180°, 270°, 360°
selectable
Crop plane: ON/OFF
Multi-Slice: Ref A, Ref B, Ref C
Slice Spacing: 0.5-2.0, adjustable
Slice number: 9, 16 or 25
Measurement: Distance, Area, Volume
Slice position: adjustable
ROI size adjustable
ROI sample line curvature: adjustable
X Rotation
Y Rotation
Z Rotation
Zoom In/Out: adjustable
Horizontal Movement: Left/Right
Vertical Movement: Up/Down
Free Rotation
 
3D Image/Volume Storage
Print Function
 
 
4D Mode
Customized preset
Cine Playback: ON/OFF
Methods for cropping reviews
By trace (crop inner or outer image) By box (crop inner or outer image) By eraser (big or small eraser)
Undo cut: undo last cut
Display Mode
Dual-split display
Quad-split display
3D Full Display
4D Full Display
Contrast: 0-100 adjustable
Transparency: 0-100 adjustable
Brightness: 0-100 adjustable
Smoothness: 0-30 adjustable
3D Chroma: 0-12 adjustable
B Chroma: 1-13 adjustable
n      View angle: 0°, 90°, 180°, 270°
Restore: Volume/All/Curve, selectable
Render Mode: Vol, MaxIP, X ray
Orientation: Top, Bottom, Left, Right, Front or Back selectable
l      Auto Rotate: 45°, 90°, 180° , 270°and 360°, selectable
Multi-Slice: Ref A, Ref B, Ref C
Slice Spacing: 0.5-2.0, adjustable
Slice number: 9, 16 or 25
Measurement: Distance, Area, Volume
Slice position: adjustable

 
 
 
Sample Line Curvature: adjustable
ROI Size and Position: adjustable
Focus position: adjustable
Image Quality: High, Medium, Low
Scan angle : 5°-75°, adjustable
Stability: On/Off
X Rotation
Y Rotation
Z Rotation
Zoom In/Out: adjustable
Horizontal Movement: Left/Right
Vertical Movement: Up/Down
Free Rotation
Cine Playback: The range depends on the volume data.)
3D Image/Cine/Volume Storage
User-defined mode
Print function
 
 
Physiological Signal Display
ECG Pulse wave
ECG Lead-three lead system
ECG Gain: adjustable
ECG Position: adjustable
ECG Invert: On/Off
R-Trigger: On/Off
Trigger Delay: adjustable
Frame Count: adjustable
 
 
Integrated Data Management System
Hard Disk Memory Capacity: 500G
USB ports: 3 (including 1 engineering port)
Image Storage and Playback
Cine Loop: Up to 1000 frames in B mode
Real time single or dual display, static or dynamic image storage
The Stored Images can be viewed directly on PC.
Clip Board Function (In frozen B mode)
Doppler Cine Playback: Speed is adjustable; Sound can be played back.
 
 
DICOM Network Communication
Storage: Directly transmits images with patient information to a DICOM file server
Print: Images can be printed directly using a DICOM compatible printer
DICOM Storage Commitment
DICOM Worklist
DICOM MPPS
DICOM Q/R
Medical digital images and communication DICOM 3.0 interface
 
 
Preset Function
Users can customize the presets based on different probe and diagnostic part to optimize imaging parameters and adjustment combination.
Preset sequence adjustable
Import/export the preset
 
 
Patient Data Management
Patient Registration: Name, ID, Gender, Date of Birth, Height, Weight, LMP, EDD and GA.
Patient data and reports are archived by patient
exams
 
 
 
Reports and images can be previewed.
Preview size can be set to 1*1, 2*2, 3*3 .
Previewed file can be deleted, previewed, DICOM send or DICOM print.
Data can be exported to USB drive or DVD in BMP, JPG, TIF, AVI or WMV format.
 
 
Annotation and Body Mark Setting
Body Mark Icon: Classified by department
Annotation can be selected and input in the library.
 
 
Physical Specification
l      Size: 413mm*357 mm*391mm (L*W*D)
 
Weight: Approx. 7.9kg
Monitor: 15'' Widescreen and High-Resolution Color LCD monitor,LED backlight, anti-flickering and vertically and horizontally rotatable
Probe connector: 2, interchangeable
 
 
Safety Standard
Comply with IEC60601-1, Class I,BF type
 
 
 
Environmental Requirements
Operation Environment
Temperature:+10ºC to +40ºC
 
Relative Humidity: 30% to 85% (non condensing)
Atmospheric pressure: 700 to 1060hPa
Transportation and Storage Environment
Temperature: -20ºC to +55ºC
 
Relative humidity: 20%- 90% (non condensing)
 
Atmospheric Pressure: 700 to 1060hPa
Power Supply
n      110-240~, 2.7-1.2A
Frequency: 50/60Hz
 
 
Optional Probes
Phased Array Probes
2P2 (Frequency: 1.0-6.0MHz, sweep angle: 85°)
5P1 (Frequency: 3.0-9.0MHz, sweep angle: 87°)
MPTEE mini (Frequency: 4.0-13.0MHz, sweep angle: 90°)
Linear Probes
n      L741 (4.0-16.0 MHz)
n      L742 (4.0-16.0 MHz)
n      L752 (4.0-16.0 MHz)
n      10I2 (4.0-16.0 MHz)
n      L743 (4.0-16.0 MHz)
n      LAP7 (3.0-15.0MHz)
Convex Probes
n      3C-A (1.0-7.0 MHz)
n      C344 (2.0-6.8 MHz)
n      C353 (2.0-6.8 MHz)
n      C322 (2.0-6.8 MHz)
n      C354 (2.0-6.8 MHz)
n      6V3 (3.0-15.0 MHz)
n      EC9-5 (3.0-15.0 MHz)
n      C611 (4.0-13.0 MHz)
n      C613 (4.0-13.0 MHz)
n      6V1 (3.0-15.0MHz)
Volume Probes
n      VC6-2 (2.0-6.8MHz)
Biplane Probes

 
 
BCC9-5
n      BCL10-5
 
 
Measurements and Calculations
 
Basic Measurements and Calculations
B Mode
 
Measurement CollectionMeasurement Item
DistanceTwo-Point Measurement, Length Trace Measurement, Distance Ratio Measurement, %Stenosis Distance
AreaTrace Area Measurement, Ellipse Area Measurement, Area Ratio Measurement, %Stenosis Area
VolumeThree-distance Measurement, Distance + Ellipse Measurement
AngleThree-Point Angle Measurement, Two-Line Angle Measurement
 
M Mode
 
Measurement CollectionMeasurement Item
 
Basic Measurements
Distance Measurement, Slope Measurement, %Stenosis Distance Measurement, Distance Ratio Measurement, Time Measurement, Heart Rate Measurement
 
Color-Flow Mode
 
Measurement CollectionMeasurement Item
DistanceTwo-Point Measurement, Length Trace Measurement, Distance Ratio Measurement, %Stenosis Distance
AreaTrace Area Measurement, Ellipse Area Measurement, Area Ratio Measurement, %Stenosis Area
VolumeThree-distance Measurement, Distance + Ellipse Measurement
AngleThree-Point Angle Measurement, Two-Line Angle Measurement
Color FlowDoppler Area Measurement, Color Flow Measurement, Flow Velocity Measurement
 
Spectral Doppler-Mode
 
Measurement CollectionMeasurement Item
 
Basic Measurements
Velocity Measurement, Acceleration Measurement, Resistivity Index Measurement, Pulsatility Index Measurement, S/D Ratio Measurement, Auto Trace Measurement, Manual Trace Measurement, Time Measurement, Heart Rate Measurement

 
 
Obstetrics Measurements and Calculations
B Mode
Measurements

 
Measurement CollectionMeasurement Item
Fetal BiometryBPD, OFD, HC, AC, FL, HL, Vp, CM, Cereb, NF
Early GestCRL, GS, YS, BPD, FL, NT
Long BonesHL, Clav., RAD, Ulna, TIB, FIB
Fetal CraniumCereb., CM, Va, Vp, BOD, IOD, HEM, c.s.p, NT, NF
AFIQ1, Q2, Q3, Q4
UterusLength, Height, Width, Endo.Thickn., Cervix Length
Lt(Rt) OvaryLength, Height, Width
Umbilical VeinDiameter
Lt(Rt) Uterine ADiameter
Calculations
 
GA
EDD
EFW
AUA
CUA
 
M Mode
 
Measurement CollectionMeasurement Item
GenericDistance, Slope, Time, HR, Stenosis % Distance
FHRFHR, AtrialFHR
 
Spectral Doppler Mode
 
Measurement CollectionMeasurement Item
 
Ductus Art
Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED, RI, SD, HR
 
Ao
Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED, RI, SD,HR
 
Lt(Rt) Carotid
Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED, RI, SD, HR
 
Lt(Rt) MCA
Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED, RI, SD, HR

 
 
Measurement CollectionMeasurement Item
 
Umbilical Art.
Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED, RI, SD, HR
Umbilical VeinTAmax
Ductus VenS, D, a, PVIV, HR
 
Lt(Rt) Uterine Art.
Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED, RI, SD, HR
FHRFHR
 
SMA
Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED, RI, SD, HR
 
Celiac.A.
Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED, RI, SD, HR
IVCS, D, S,a, PLI, PVIV
 
Lt(Rt)UmA
Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED, RI, SD, HR
 
Gynecology Measurements and Calculations
B Mode
 
Measurement CollectionMeasurement Item
UterusLength, Height, Width, Endo.Thickn., Cervix Length
Lt(Rt) Uterine ADiameter
Lt(Rt)OvaryLength, Height, Width
Lt(Rt) FollicleFollicle
FibroidFibroid
 
M Mode
 
Measurement CollectionMeasurement Item
Lt(Rt) Ovarian Art.Vessel Diameter, Stenosis Diameter, Time, HR
Lt(Rt) Uterine Art.Vessel Diameter, Stenosis Diameter, Time, HR
FHRFHR, Atrial FHR
 
Spectral Doppler Mode
 
Measurement CollectionMeasurement Item
Lt(Rt) Ovarian Art.Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED, RI, SD, Time, HR
Lt(Rt) Uterine Art.Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED,

 
 
Measurement CollectionMeasurement Item
 RI, SD, Time, HR
 
Vessel
Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED, RI, SD, Time, HR
FHRFHR
 
Cardiology Measurements and Calculations
B Mode
 
Measurement CategoryMeasurement CollectionMeasurement Item
 
 
Dimensions
 
 
None
IVSd, LVIDd, LVPWd, IVSs, LVIDs, LVPWs, RVOT, AO, LA, ACS, LVOT, RVAWd, RVIDd, EPSS, MCS, MV Diam, AVA, MVA, MPA, PV Diam, TV
Diam
 
 
 
 
Volume
Simp(LV)A4Cd, A4Cs, A2Cd, A2Cs
A-L(LV)LVd, LVs
Simp(LA)A4Cs, A2Cs
Simp(RA)A4Cs
Teichlozs(LV)IVSd, LVIDd, LVPWd, IVSs, LVIDs, LVPWs
 
 
LV Mass
LV Mass (Cube)IVSd, LVIDd, LVPWd
LV Mass (A-L)LVAd Sax Epi, LVAd Sax Endo, LVLd Apical
LV Mass (T-E)LVAd Sax Epi, LVAd Sax Endo, a, d
 
Color-Flow Mode
 
Measurement CategoryMeasurement CollectionMeasurement Item
 
 
 
Dimensions
 
 
 
None
IVSd, LVIDd, LVPWd, IVSs, LVIDs, LVPWs, RVOT, AO, LA, ACS, LVOT, RVAWd, RVIDd, EPSS, MCS, MV Diam, AVA, MVA, MPA, PV Diam, TV
Diam
 
 
 
 
 
Volume
Simp(LV)A4Cd, A4Cs, A2Cd, A2Cs
A-L(LV)LVd, LVs
Simp(LA)A4Cs, A2Cs
Simp(RA)A4Cs
 
Teichlozs(LV)
IVSd, LVIDd, LVPWd, IVSs, LVIDs, LVPWs
LV MassLV Mass (Cube)IVSd, LVIDd, LVPWd

 
 
Measurement CategoryMeasurement CollectionMeasurement Item
  
LV Mass (A-L)
LVAd Sax Epi, LVAd Sax Endo, LVLd Apical
LV Mass (T-E)LVAd Sax Epi, LVAd Sax Endo, a, d
 
 
 
 
 
 
PISA
 
PISA-MR
MR Rad, MR VTI (gray in the Doppler mode)
 
PISA-AR
AR Rad, AR VTI (gray in the Doppler mode)
 
PISA-TR
TR Rad, TR VTI (gray in the Doppler mode)
 
PISA-MS
MS Rad, MS VTI (gray in the Doppler mode)
 
M Mode
 
Measurement CategoryMeasurement CollectionMeasurement Item
 
 
Dimensions
 
 
None
IVSd, LVIDd, LVPWd, IVSs, LVIDs, LVPWs, RVOT, AO, LA, ACS, LVOT, RVAMd, RVIDd, EPSS, MCS
 
 
 
Time/Slope
 
/
LVPEP, LVET, RVPEP, RVET, MV DE, MV E-F Slope, MV E Amp, MV A
Amp
LV TEIMV C-O Dur, LVET
RV TEITV C-O Dur, RVET
 
 
Volume
 
Teichlozs(LV)
IVSd, LVIDd, LVPWd, IVSs, LVIDs, LVPWs
 
Cube(LV)
IVSd, LVIDd, LVPWd, IVSs, LVIDs, LVPWs
LV MassLV MassIVSd, LVIDd, LVPWd
 
Spectral Doppler Mode
 
 
Measurement Category
 
Measurement Collection
 
Measurement Item
 
 
MV
 
 
None
MV E Vel, MV A Vel, MV E Dur, MV A Dur, MVA(PHT), MV DecT, MR Vmax, MR VTI
MVA(VTI)LVOT, LVOT VTI, MV VTI

 
 
 
 
MV
LV TEIMV C-O Dur, LVET
PISA-MRMR Rad, MR VTI
PISA-MSMS Rad, MS VTI
 
 
 
 
AV
 
 
None
AV Vmax, AV VTI, AR Vmax, AR VTI, LVET, LVPEP, IVCT, IVRT, AR DecT, AR PHT, HR-AV
AVA(VTI)LVOT, LVOT VTI, AV VTI
AVA(Vmax)LVOT, LVOT Vmax, AV Vmax
PISA-ARAR Radius, AR VTI
 
 
 
 
TV
NoneTV Vmax, TV VTI
E/ATV E Vel, TV A Vel
RV TEITV C-O Dur , RVET
RVSPTR Vmax, RAP
PISA-TRTR Rad, TR VTI
 
 
 
 
PV
 
 
None
PR Vmax, PR VTI, PV AccT, MPA
Vmax, RPA Vmax, LPA Vmax, RVET, RVPEP, HR-PV
PAEDPPR Ved, RAP
PVA(Vmax)RVOT, RVOT Vmax, PV Vmax
PVA(VTI)RVOT, RVOT VTI, PV VTI
 
 
Pulm&Hep Vein
 
 
None
Pulm S Vel, Pulm S VTI, Pulm A Vel, Pulm D Vel, Pulm D VTI, Pulm A Dur, Pulm DecT, Hep S Vel, Hep D Vel, Hep A Ve, Hep A Dur
 
TDI
 
/
Sa Medial, Ea Medial, Aa Medial, Sa lateral, Ea lateral, Aa lateral
 
Abdomen Measurements and Calculations
B Mode
 
Measurement CollectionMeasurement Item
LiverLength, Height, Width
Port VeinPortal Vein Diameter, Flow Diameter
GallbladderLength, Height, Width, Wall, CBD
PancreasDuct., Head, Body, Tail
SpleenLength, Height, Width

 
 
Measurement CollectionMeasurement Item
KidneyLength, Height, Width
 
Renal Aorta
Vessel Area, Stenosis Area, Vessel Diameter, Stenosis Diameter, Flow Diameter
 
Aorta
Vessel Area, Stenosis Area, Vessel Diameter, Stenosis Diameter, Flow Diameter
BladderLength, Height, Width
 
M Mode
 
Measurement CollectionMeasurement Item
Renal AortaVessel Diameter, Stenosis Diameter, Time, HR
AortaVessel Diameter, Stenosis Diameter, Time, HR
 
Spectral Doppler Mode
 
Measurement CollectionMeasurement Item
 
Renal Aorta
Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED, RI, SD, Time, HR
 
Aorta
Auto Trace, Manual Trace, PS, ED, RI, PI, PS, ED, RI, SD, Time, HR
Port VeinVelocity, Time
 
 
Vascular Measurement
B Mode
 
 
Measurement Category
 
Measurement Collection
 
Measurement Item
 
 
 
 
 
 
 
 
Carotid
 
Lt(Rt) Subclav A
 
 
 
 
 
Vessel Diam Vessel Area
%Stenosis Diam
%Stenosis Area IMT
 
Lt(Rt) CCA
 
Lt(Rt) Bulb
 
Lt(Rt) ICA
 
Lt(Rt) ECA
 
Lt(Rt) Vertebral A

 
 
 
Measurement Category
 
Measurement Collection
 
Measurement Item
 
 
 
 
 
 
 
 
 
UE Art
 
Lt(Rt) Innom A
 
 
 
 
 
Vessel Diam Vessel Area
%Stenosis Diam
%Stenosis Area IMT
 
Lt(Rt) Subclav A
 
Lt(Rt) Axill A
Lt(Rt) Brach A
Lt(Rt) Rad A
Lt(Rt) Ulnar A
Lt(Rt) Sup Palm A
Lt(Rt) Deep Palm A
 
 
 
 
 
 
 
 
 
 
UE Vein
Lt(Rt) Innom V 
 
 
 
 
 
 
Vessel Diam Vessel Area
%Stenosis Diam
%Stenosis Area IMT
Lt(Rt) Subclav V
Lt(Rt) Int Jugular V
Lt(Rt) Axill V
Lt(Rt) Ceph V
Lt(Rt) Basilic V
Lt(Rt) Brach V
 
Lt(Rt) Med Cub V
 
Lt(Rt) Rad V
 
Lt(Rt) Ulnar V
 
 
 
 
 
 
 
LE Art
 
Lt(Rt) Com Iliac A
 
 
 
 
Vessel Diam Vessel Area
%Stenosis Diam
%Stenosis Area IMT
 
Lt(Rt) Ext Iliac A
 
Lt(Rt) Int Iliac A
 
Lt(Rt) Com Fem A
 
Lt(Rt) SFA

 
 
 
Measurement Category
 
Measurement Collection
 
Measurement Item
 
 
 
 
 
 
LE Art
 
Lt(Rt) PFA
 
 
 
Vessel Diam Vessel Area
%Stenosis Diam
%Stenosis Area IMT
Lt(Rt) Popl A
Lt(Rt) Ant Tib A
Lt(Rt) Post Tib A
Lt(Rt) Peron A
Lt(Rt) Dors Ped A
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
LE Vein
Lt(Rt) IVC 
 
 
 
 
 
 
 
 
 
 
 
Vessel Diam Vessel Area
%Stenosis Diam
%Stenosis Area IMT
Lt(Rt) Com Iliac V
Lt(Rt) Ext Iliac V
Lt(Rt) Int Iliac V
Lt(Rt) Com Fem V
Lt(Rt) SFV
Lt(Rt) PFV
 
Lt(Rt) Popl V
 
Lt(Rt) Ant Tib V
 
Lt(Rt) Post Tib V
 
Lt(Rt) Peron V
 
Lt(Rt) GSV Thigh
 
Lt(Rt) GSV Calf
Lt(Rt) LSV

 
 
M Mode
 
 
Measurement Category
 
Measurement Collection
 
Measurement Item
 
 
 
 
 
 
 
Carotid
 
Lt(Rt) Subclav A
 
 
 
 
Vessel Diam
%Stenosis Diam Time
HR
 
Lt(Rt) CCA
 
Lt(Rt) Bulb
 
Lt(Rt) ICA
 
Lt(Rt) ECA
Lt(Rt) Vertebral A
 
 
 
 
 
 
 
 
 
UE Art
 
Lt(Rt) Innom A
 
 
 
 
Vessel Diam
%Stenosis Diam Time
HR
 
Lt(Rt) Subclav A
 
Lt(Rt) Axill A
Lt(Rt) Brach A
Lt(Rt) Rad A
Lt(Rt) Ulnar A
Lt(Rt) Sup Palm A
Lt(Rt) Deep Palm A
 
 
 
 
 
 
 
 
UE Vein
Lt(Rt) Innom V 
Vessel Diam
%Stenosis Diam Time
HR
Lt(Rt) Subclav V
Lt(Rt) Int Jugular V
Lt(Rt) Axill V
Lt(Rt) Ceph V
Lt(Rt) Basilic V
Lt(Rt) Brach V
 
Lt(Rt) Med Cub V

 
 
 
Measurement Category
 
Measurement Collection
 
Measurement Item
 
 
 
UE Vein
 
Lt(Rt) Rad V
 
Vessel Diam
%Stenosis Diam Time
HR
 
Lt(Rt) Ulnar V
 
 
 
 
 
 
 
 
 
 
 
 
 
LE Art
 
Lt(Rt) Com Iliac A
 
 
 
 
 
 
 
 
Vessel Diam
%Stenosis Diam Time
HR
 
Lt(Rt) Ext Iliac A
 
Lt(Rt) Int Iliac A
 
Lt(Rt) Com Fem A
 
Lt(Rt) SFA
 
Lt(Rt) PFA
Lt(Rt) Popl A
Lt(Rt) Ant Tib A
Lt(Rt) Post Tib A
Lt(Rt) Peron A
Lt(Rt) Dors Ped A
 
 
 
 
 
 
 
 
 
 
 
 
 
LE Vein
Lt(Rt) IVC 
 
 
 
 
 
Vessel Diam
%Stenosis Diam Time
HR
Lt(Rt) Com Iliac V
Lt(Rt) Ext Iliac V
Lt(Rt) Int Iliac V
Lt(Rt) Com Fem V
Lt(Rt) SFV
Lt(Rt) PFV
 
Lt(Rt) Popl V
 
Lt(Rt) Ant Tib V

 
 
 
Measurement Category
 
Measurement Collection
 
Measurement Item
 
 
 
 
 
LE Vein
 
Lt(Rt) Post Tib V
 
 
 
 
Vessel Diam
%Stenosis Diam Time
HR
 
Lt(Rt) Peron V
 
Lt(Rt) GSV Thigh
 
Lt(Rt) GSV Calf
Lt(Rt) LSV
 
 
Spectral Doppler Mode
 
 
Measurement Category
 
Measurement Collection
 
Measurement Item
 
 
 
 
 
 
 
Carotid
 
Lt(Rt) Subclav A
 
Auto Trace Manual Trace PS
ED RI PI
PS, ED, RI, SD HR
 
Lt(Rt) CCA
 
Lt(Rt) Bulb
 
Lt(Rt) ICA
 
Lt(Rt) ECA
Lt(Rt) Vertebral A
 
 
 
 
 
 
 
 
 
UE Art
 
Lt(Rt) Innom A
 
 
 
 
 
Auto Trace Manual Trace PS
ED RI PI
PS, ED, RI, SD HR
 
Lt(Rt) Subclav A
 
Lt(Rt) Axill A
Lt(Rt) Brach A
Lt(Rt) Rad A
Lt(Rt) Ulnar A
Lt(Rt) Sup Palm A
 
Lt(Rt) Deep Palm A

 
 
 
Measurement Category
 
Measurement Collection
 
Measurement Item
 
 
 
 
 
 
 
 
 
 
 
UE Vein
Lt(Rt) Innom V 
 
 
 
Auto Trace Manual Trace PS
ED RI PI
PS, ED, RI, SD HR
Lt(Rt) Subclav V
Lt(Rt) Int Jugular V
Lt(Rt) Axill V
Lt(Rt) Ceph V
Lt(Rt) Basilic V
Lt(Rt) Brach V
 
Lt(Rt) Med Cub V
 
Lt(Rt) Rad V
 
Lt(Rt) Ulnar V
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
LE Art
 
Lt(Rt) Com Iliac A
 
 
 
 
 
 
 
 
 
Auto Trace Manual Trace PS
ED RI PI
PS, ED, RI, SD HR
 
Lt(Rt) Ext Iliac A
 
Lt(Rt) Int Iliac A
 
Lt(Rt) Com Fem A
 
Lt(Rt) SFA
 
Lt(Rt) PFA
 
Lt(Rt) Popl A
 
Lt(Rt) Ant Tib A
 
Lt(Rt) Post Tib A
 
Lt(Rt) Peron A
 
Lt(Rt) Dors Ped A

 
 
 
Measurement Category
 
Measurement Collection
 
Measurement Item
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
LE Vein
Lt(Rt) IVC 
 
 
 
 
 
 
 
 
 
 
Auto Trace Manual Trace PS
ED RI PI
PS, ED, RI, SD HR
Lt(Rt) Com Iliac V
Lt(Rt) Ext Iliac V
Lt(Rt) Int Iliac V
Lt(Rt) Com Fem V
Lt(Rt) SFV
Lt(Rt) PFV
 
Lt(Rt) Popl V
 
Lt(Rt) Ant Tib V
 
Lt(Rt) Post Tib V
 
Lt(Rt) Peron V
 
Lt(Rt) GSV Thigh
 
Lt(Rt) GSV Calf
Lt(Rt) LSV
 
 
Urology Measurement
B Mode
 
 
Measurement Collection
 
Measurement Item
 
Lt(Rt) Kidney
 
Length, Height, Width, Renal Cortex
 
Lt(Rt) Renal A
 
Vessel Diam, Vessel Area, %Stenosis Diam, %Stenosis Area
 
Lt(Rt) Vessel
 
Vessel Diam, Vessel Area, %Stenosis Diam, %Stenosis Area
 
Lt(Rt) Suprarenal
 
Length, Height, Width
 
Bladder
 
Length, Height, Width

 
 
 
Measurement Collection
 
Measurement Item
 
Prostate
 
Length, Height, Width
 
Lt(Rt) Testicle
 
Length, Height, Width
 
 
M Mode
 
 
Measurement Collection
 
Measurement Item
 
Lt(Rt) Renal A
 
Vessel Diam, %Stenosis Diam, Time, HR
 
Lt(Rt) Vessel
 
Vessel Diam, %Stenosis Diam, Time, HR
 
 
Spectral Doppler Mode
 
 
Measurement Collection
 
Measurement Item
 
Lt(Rt) Renal A
 
Auto Trace; Manual Trace; PS; ED; RI; PI; PS, ED, RI, SD; HR
 
Lt(Rt) Vessel
 
Auto Trace; Manual Trace; PS; ED; RI; PI; PS, ED, RI, SD; HR
 
 
Small Part Measurement
Thyroid
B Mode

 
Measurement CollectionMeasurement Item
 
Lt(Rt) Thyroid
 
Length, Height, Width
 
Lt(Rt) Sup. ParThyroid
 
Length, Height, Width
 
Lt(Rt) Inf. ParThyroid
 
Length, Height, Width
 
Thyroid Ist.
 
Length, Height, Width
 
Lt(Rt) STA
 
 
Vessel Diam
 
Lt(Rt) ITA

 
 
M Mode
 
Measurement CollectionMeasurement Item
 
Lt(Rt) STA
 
Vessel Diam, Time, HR
 
Lt(Rt) ITA
 
Vessel Diam, Time, HR
 
 
Spectral Doppler Mode
 
Measurement CollectionMeasurement Item
 
Lt(Rt) STA
 
Auto Trace; Manual Trace; PS; ED; RI; PI; PS, ED, RI, SD; Time; HR
 
Lt(Rt) ITA
 
Auto Trace; Manual Trace; PS; ED; RI; PI; PS, ED, RI, SD; Time; HR
 
 
Testicle
B Mode

 
 
Measurement Collection
 
Measurement Item
 
Lt(Rt) Testicle
 
Length, Height, Width
 
 
M Mode
 
 
Measurement Collection
 
Measurement Item
 
Lt(Rt) Vessel
 
Vessel Diam, Time, HR
 
 
Spectral Doppler Mode
 
 
Measurement Collection
 
Measurement Item
 
Lt(Rt) Vessel
 
Auto Trace; Manual Trace; PS; ED; RI; PI; PS, ED, RI, SD; Time; HR

 
 
Breast
B Mode

 
 
Measurement Collection
 
Measurement Item
 
Lt(Rt) Lesion1-5
 
Nipple-Les. Dist, Skin-Les. Dist, Length, Width, Height
 
 
M Mode
 
 
Measurement Collection
 
Measurement Item
 
Vessel
 
Vessel Diam, Stenosis Diam, Time, HR
 
 
Spectral Doppler Mode
 
 
Measurement Collection
 
Measurement Item
 
Vessel
 
Auto Trace; Manual Trace; PS; ED; RI; PI; PS, ED, RI, SD; Time; HR
 
 
Pediatrics Measurement
B Mode
 
 
Measurement Collection
 
Measurement Item
 
Hip
 
Hip Angle, Hip d-D Ratio
 
 
Calculation Reports
Reports for each departments
 
 
Classification
 
Descriptions
 
Vascular report
 
/
 
 
 
 
Obstetrics report
 
Measurement report Fetal growth curve report
Fetal anatomical survey report Fetus compare (quadruplet) Comments

 
 
 
Classification
 
Descriptions
 
Gynecology report
 
/
 
Small part report
 
/
 
Cardiac report
 
/
 
Urology report
 
/
 
Abdomen report
 
/
 
Pediatrics report
 
/
 
 
Measurement values in the report are editable.
Image: selectable
Information such as hospital name can be preset.
Report can be output as HTML format.

 
 
 
 
 